60227 IEC 52 RVV 300 / 300V Flexible Building Wire Light PVC Insulated PVC Sheath

60227 IEC 52 RVV 300 / 300V Flexible Building Wire Light PVC Insulated PVC Sheath

Iinkcukacha:

    I-60227 IEC 52 (RVV) Ikhaphu yePVC eneSheathed Flexible Cable yokuLungisa iiNcingo.
    Ikwasetyenziswa kufakelo lwamandla, isixhobo sombane sasekhaya, isixhobo, izixhobo zonxibelelwano, ulawulo lokutshintsha, iiphaneli zokuhambisa umbane kunye nezixhobo zesixhobo sokutshintsha amandla kunye neenjongo ezinjengeziqhagamshelo zangaphakathi kwisixhobo sokulungisa, iziqalisi zeemoto kunye nezilawuli.

     

Iinkcukacha eziKhawulezayo

Itheyibhile yeParameter

Iithegi zeMveliso

Iinkcukacha eziKhawulezayo:

UkuKhanya kwePVC egqunywe ngePVC Sheath RVV Flexible Building Wire for Internal Wiring

Usetyenziso:

I-60227 IEC 52 RVV 300/300V iFlexible Building Wire ilungele izixhobo zasekhaya, iplanti kunye noomatshini, injongo yocingo kunye nokwenza iintambo.Ubhedu olungenanto, i-conductor yocingo oluhle, kukho ii-cores ezi-2 kunye ne-3 cores onokukhetha kuyo.Amandla ombane alinganisiweyo yi-300/300V.

.

Ukusebenza koBugcisa:

Umbane olinganisiweyo (Uo/U):300/300V
Iqondo lobushushu leKonda:Elona qondo liphezulu lobushushu be-conductor kusetyenziso oluqhelekileyo: 70ºC
Ubushushu bokufaka:Ubushushu be-Ambient phantsi kofakelo abuyi kuba ngaphantsi kwe-0ºC
Ubuncinci beradiyasi yokugoba:
Iradiyasi yokugoba yentambo: (I-D-Diameter yentambo)
D≤25mm------------------≥4D
D>25mm------------------≥6D


Ulwakhiwo :

IKondi:Inani labaqhubi: 2,3 okanye enye i-multi-core.
Abaqhubi baya kuthobela imfuno enikwe kwi-IEC 60228 yeklasi 5.
Ukudityaniswa kwee-cores:

Intambo eSetyhula: ii-cores ziya kuphothwa kunye.
Intambo ecaba: iicores ziya kubekwa ngokuhambelanayo.
Ukhuselo:IPVC(Polyvinyl Chloride) Uhlobo lwePVC/D ngokwe-IEC
Isingxobo:I-PVC (i-Polyvinyl Chloride) Uhlobo lwe-PVC/ST5 ngokwe-IEC

Iinkcukacha:

60227 IEC 52 esemgangathweni

Qhagamshelana nathi:

Ukuba nayiphi na kwezi zinto inomdla kuwe, nceda usazise.Siyakwaneliseka kukunika ikowuti emva kokuba sifumene iinkcukacha zomntu.Sinobunjineli bethu abanamava e-R&D ukuhlangabezana nazo naziphi na iimfuno zomntu, Sijonge phambili ekufumaneni imibuzo yakho kungekudala kwaye sinethemba lokuba nethuba lokusebenza kunye nawe kwixa elizayo.Wamkelekile ukujonga inkampani yethu.

60227 IEC 52 Ukukhanya kwePVC efakwe kwi-PVC Sheath RVV ngocingo loKwakha oluGuquguqukayo

INdawo yoMnqamlezo yoMnqamlezo yoMmandla woMqhubi Udidi lomqhubi Ukutyeba kwe-Insulation ye-Nominal Ukutyeba kwesingxobo segama Ubukhulu beDayamitha iyonke Max.DCResistance ku-20 ℃ (Ω/km) Min.Insulation Resistance kwi-70 ℃
(mm²) / (mm) (mm) (mm) Ngokucacileyo I-Metal-coated (Ω/km)
2×0.5 5 0.5 0.6 5.9 39 39 0.012
2×0.5 5 0.5 0.6 3.7×5.9 24 39 0.012
2×0.75 5 0.5 0.6 6.3 46 26 0.01
2×0.75 5 0.5 0.6 3.8×6.3 31 26 0.01
3×0.5 5 0.5 0.6 6.3 49 19.5 0.012
3×0.75 5 0.5 0.6 6.7 60 19.5 0.01